CNAPlay › Rhode Island CNA skills › Manual Blood Pressure
Manual Blood Pressure: Rhode Island CNA skills test steps
These are the 12 steps the evaluator scores for Manual Blood Pressure on the Rhode Island CNA skills test, from the Credentia checklist. Read them, then play the free game until you can do every step in order.
- Explains procedure, speaking clearly, slowly, and directly, maintaining face-to-face contact whenever possible
- Before using stethoscope, wipes bell/diaphragm and earpieces of stethoscope with alcohol
- Client's arm is positioned with palm up and upper arm is exposed
- Feels for brachial artery on inner aspect of arm, at bend of elbow
- Places blood pressure cuff snugly on client's upper arm, with sensor/arrow over brachial artery site
- Earpieces of stethoscope are in ears and bell/diaphragm is over brachial artery site
- Candidate inflates cuff between 160mm Hg to 180 mm Hg. If beat heard immediately upon cuff deflation, completely deflate cuff. Re-inflate cuff to no more than 200 mm Hg
- Deflates cuff slowly and notes the first sound (systolic reading), and last sound (diastolic reading). Measurements rounded to nearest 2 mm of mercury if needed
- Removes cuff
- Signaling device is within reach
- Before recording, washes hands
- After obtaining reading using BP cuff and stethoscope, records both systolic and diastolic pressures each within plus or minus 8 mm of evaluator's reading
Practice Manual Blood Pressure free
More Rhode Island CNA skills
- Hand Hygiene
- Elastic Stocking
- Assist to Ambulate
- Bedpan Assistance
- Clean Dentures
- Radial Pulse
- Respirations
- Donning & Removing PPE
- Dresses Client (Weak Arm)
- Feeds Client
- Modified Bed Bath
- Electronic Blood Pressure
- Urinary Output
- Weight Measurement
- Passive Range of Motion
- PROM - Shoulder
- Positions on Side
- Catheter Care - Female
- Foot Care
- Mouth Care
- Peri-Care Female
- Transfer to Wheelchair